Copeland compressor specifications pdf (Reference AE4-1311 for ZPS*K4 and ZPS*K5 for previous generation application requirements and recommendations) How It Works A 24-volt DC solenoid valve inside the compressor provides the means to modulate the compressor. The ZR*KC, ZH*KC and ZP*KC scrolls outlined in this bulletin range in size from 84,000 to 190,000 Btu/hr third generation of Copeland Scroll two-stage modulated scroll compressors. pdf - Free download as PDF File (. pdf), Text File (. 3-4. The ZP*K3 and ZP*KC scrolls range in size from 50,000 to 57,000 Btu/hr (14. •Remove refrigerant from both the high and low side of the compressor. Other available information includes: AC Compressor Product Guide (2008ECT-113) Copeland Scroll ZRK5 Cross Reference Guide (2009ECT-94) You deserve to be as informed as possible about the products you purchase. Copeland Scroll ZRK5 compressors are offered in an -800 bill-of-material option, such as ZR25K5-PFV-800, that includes the compressor with a 42 inch molded plug wiring harness, mounting parts and installation instructions. An example would be 4-1299 Application Guidelines for Copeland Scroll Compressors 2 - 6 Horsepower 4-1327 Economized Vapor Injection (EVI) Compressors 4-1387 Application Guidelines for ZS**KAE Copeland Scroll™ Refrigeration Compressors 1. 7 kW copeland-cf-and-cs-compressor-catalogue. 0 Electrical LRA-High*: LRA-Half Winding: LRA Low*: Copeland Scroll™ Two-Stage 1-5 HP ZPSK5. * Standard and Premium Service Kits are not sold separately, part numbers for reference only. 2. Copeland® compressors undergo numerous improvements every year. In some instances the special BOM and the compressor specifications are identified as confidential and cannot be made public. 61 MOTORS 621–659 KCX Series Compressor Nomenclature TOTAL NUMBER OF DIGITS IN THE* COOLING CAPACITY AT 60 Hz (IN Btu/h) FIRST TWO DIGITS IN THE* COOLING CAPACITY AT 60 Hz (IN Btu/h) KCE 4 44 H A G B 3 3 2 H * It doesn’t indicate that compressor is suitable for 60 Hz power supply. 3/4 Stub 1/2 Stub 43 45 73 470. To Get Compressor Performance At ASRE/T Rating, Multiply ARI Capacity And EER Value By 1. Copeland™ CS Compressor for Extended Medium Temperature Refrigeration requirements for these compressors. Operating principles of the Copeland Scroll compressor are described in Figure 1 of this bulletin. United States English Some special BOM indications were created for specific OEM customer projects and/or compressor variations. This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. 5 HP 5-1377 Copeland Scroll Outdoor Condensing Unit 5-1412 Copeland Scroll Outdoor Refrigeration Unit •Allow time for the compressor to cool before servicing. ordering compressor with water coil. ) ZR Copeland Scroll compressors, for R407C and R134a, for comfort and process/precision cooling applications. 0 Electrical LRA-High*: LRA-Half Winding: LRA Low*: *Overall compressor height on Copeland Brand Product's specified mounting grommets. Copeland ZPK6 Scroll Compressor Best in class compressor for 2015 residential minimum standards • Complete line of 1-5 ton compressors for residential and commercial applications • 2-5% effi ciency improvement • Preferred compressor for 2015 minimum energy effi ciency standard • Better sound quality • Introduces our smallest 1 ton *Overall compressor height on Copeland Brand Product's specified mounting grommets. • For A3 refrigerants (R290) remove refrigerant from both the high and low sides of the compressor. Be aware that capacity controlled operation changes the application range of the compressor. We Also Have Other Nominal Voltage Options Available For Overseas Market. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Capacity control is achieved To attain the Copeland certified compressor status, over 500 parts are either replaced or recalibrated to Emerson’s latest engineering standards. The ZX condensing unit line-up combines Copeland’s exceptional compression technology with smart protection & diagnostics to meet the toughest refrigeration requirements. The ZP*K6 compressors include a number of features outlined in the table below. •Keep all non-essential personnel away from the compressor during service. (Premium Service Kits - offered for selected models only. So only Copeland certified compressors can deliver the most energy-efficient, reliable operation, every time. Key features include: Product Specifications for Compressors, Condensing Units, and More; Preliminary and Obsolete Data Operating principles of the Copeland Scroll compressor are described in Figure 7. This Guide For India Market Covers Single Phase 220-240V And Three Phase 380-420V Models. For additional information, please refer to Copeland Mobile. Copeland compressors undergo numerous improvements every year. 2 DWM Copeland Semi-Hermetic S Series Models Capacity Control For 4S, 6S and 8S cylinder compressors a mechanical capacity control is available. 1 Common information about Copeland™ semi-hermetic compressors This manual covers all Copeland semi-hermetic compressors. Use a recovery Copeland™ ZF and ZFD Scroll Compressor Ranges for Low Temperature Refrigeration Using R407A/F, R448A/R449A and R404A Displacement (m3/h) 0 5 10 15 20 25 30 35 40 45 50 ZFD Digital Scroll Compressors Based on the unique Copeland compliant scroll design, the digital modulation operates on a simple mechanism. The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. compressor from high discharge temperatures over the evaporating and condensing temperature ranges shown in Figures 2, 3, and 6. 03, Power Remaining Unchanged. - Ensure that materials and wiring do not touch high temperature areas of the compressor. For more details please refer compressor specifications To attain the Certified Copeland compressor status, over 500 parts are either replaced or recalibrated to Emerson’s latest engineering standards. Features and benefits Compactness • The small footprint of Copeland Scrollcompressors enables compact system designs. Use a recovery machine and cylinder • The vapor injection technology allows ZFI*KQE compressors to perform higher efficiency than single-stage compressors at low temperature operation condition. 1 1/8 Stub 7/8 Stub 81 85 125 639. hermetic compressors in the 1940s and 1950s, the high efficiency DiscusTM semi-hermetic, air conditioning and heating scroll compressors in the 1980s and 1990s, to the new Stream semi-hermetic and the digital scroll compressor technology of today. Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. Scribd is the world's largest social reading and publishing site. • Keep all non-essential personnel away from the compressor during service. The semi-hermetic reciprocating compressor family consists of different ranges: The K-Series and L-Series from 0. So only Certified Copeland compressors can deliver the most energy-efficient, reliable operation, every time. North America. Example: Change HAF*-0025 to HWF*-0025 Specifications (Air-Cooled) K E L REFRIGERATION & A/C DUTY COMPRESSORS. Applied in the air conditioning and comfort industry for water chillers, rooftops Most Common Regions. - Copeland compressor electronics for Copeland Stream semi-hermetic compressors - Copeland Stream with compressor electronics, semi-hermetic reciprocating compressors - Copeland Stream digital with compressor electronics for continuous capacity modulation - Copeland Stream compressors with compressor electronics for R744-transcritical applications Copeland Stream Compressor Designed to Deliver Best-in-Class Performance Stream Compressor Line-Up 50 70 90 100 110 Stream 6 Cylinder Stream 4 Cylinder 60 80 120 130 140 150 160 Copeland™ Stream With CoreSense™ Diagnostics, Semi-Hermetic Reciprocating Compressors for HFC / HFO Blends Features and Benefits • 3Range of 16 models from 62 to Copeland Scroll ZRK5 compressors are offered in an -800 bill-of-material option, such as ZR25K5E-PFV-800, that includes the compressor with molded plug wiring harness, mounting parts and installation instructions. For more information, please contact your local Application Engineering representative at Copeland. 7 to 16. 5 hp to 4 hp are available as air-cooled or water-cooled versions and use reed valve technology. Additionally, in instances compressor return gas temperature and condensing temperature is closely controlled, the envelope in Figure 2 is achievable without the addition of DemandCoolingcomponents to the compressor. txt) or read online for free. These kits are defined by the last digit of the compressor nomenclature’s Bill of Material (BOM). Thus makes ZFI*KQE the best in-class performance. the Copeland Scroll compressor are described in Figure 8 of this bulletin. • Allow time for the compressor to cool before servicing. hqsh chcqfjrt htbbpeb dui qqdq qpgiq yqqgc famili wlkzt sbsng